DC Charger
OYFC-DC1000-120、OYFC-DC1000-150、OYFC-DC1000-180
Fast DC Charger is an auxiliary device designed to charge and replenish electric vehicles. It provides a charging interface, a HMI (human- machine interface), and other functions to control the charging of electric vehicles, enabling operations such as charging on/off and intelligent billing. The DC Charger is developed with an embedded micro-controller as its main controller, featuring user management,charging interface management, electronic certificate generation, and network monitoring. It is the man- machine platform for charging operations
Category:
KEY FEATURES
Specifications
Model | OYFC-DC1000-120 | OYFC-DC1000-150 | OYFC-DC1000-180 |
Input parameters(kW) | 120 | 150 | 180 |
Input AC Voltage(V) | 3-phases+N+PE, 260-530 | ||
DC Voltage accuracy(%) | <±0.5 | ||
Output DC voltage range(V) | DC 150-1000 | DC 200-1000 | DC 150-1000 |
Max DC output current(A) | The maximum output current of each cable is 200/CCS (optional 350), 250/GBT, 125/CHAdeMO | ||
Max DC output power(kW) | 120 | 150 | 180 |
Max system efficiency(%) | >94.5 (Rated input and output) | ||
Ambient temperature(℃) | -20~+70 , full power output below 45℃ , Power derating 5/℃ above 45℃ | ||
Function and Interface | |||
HMI | 7" TFT Touch Screen LCD,RFID,Power(G) /Alarm(R) /3*Charging(Y) panel LED | 7" TFT Touch Screen LCD,RFID,Power(G)/Alarm(R)/2*Charging(Y)panel LED,2optional Charging Start/Stop Buton | |
Metering | 1 AC energy meter and 2 DC energy meter, GB/T 50063- 2008 and DL/T 5137-2008 standard。GB/T 50063-2008 and DL/T 5137-2008 | 2 DC energy meter, GB/T 50063-2008 and DL/T 5137-2008 standard2,GB/T50063-2008 和 DL/T 5137-2008 | 1 AC energy meter and 2 DC energy meter, GB/T 50063- 2008 and DL/T 5137-2008 standard。GB/T 50063-2008 and DL/T 5137-2008 |
Monitor interface | OCPP 1.6J , LAN 10M/100M and optional inner LTE wireless modem support | ||
Charging Mode | Auto basis,Time basis,Amount basis,Energy basis,SOC basis | ||
Power Distribution Mode | Stand alone,Current switch,Plug switch,Full hold, Master slave | ||
Configuration | |||
Charger module configuration | 4 power module slots,1000V30kWCharger power modules selection | 5 power module slots,1000V30kW Charger power modules selection | 6 power module slots,1000V30kW Charger power modules selection |
Charging connector configuration | 2 CCS /2GBT /1 CCS+1 CHAdemo / 1 CCS+1 GBT, AC type2 cable or AC type2 socket | ||
Charging connector capacity | 200A/1000V for CCS, 125A/500V for CHAdeMO, 250A/750V for GBT, 32A for AC Type2 | ||
Charging connector capacity | 200A/1000V for CCS, 125A/500V for CHAdeMO,250A/750V for GBT/,32A for AC. | 2 CCS1 / 2 CCS2 / 2GBT / CCS + GBT / CCS+CHAdeMO,200A/1000V for CCS,Optional 350A with left connector, 125A/500V for CHAdeMO, 250A/750Vfor GBT. | 200A/1000V for CCS, Optional 350A with left connector, 125A/500V for CHAdeMO,250A/750V for GBT/,32A for AC. |
Protection Class | IP65/K10 | ||
Dimention | 700*1750*700 | 700*1750*860 | 650*1750*820 |
Weight(kg) | 150+11*N | 180+11*N | 130+21*N |
N is the charger module configuration number | |||
Certification | |||
CCS PLC commun ication | DIN70121 and ISO15118 | ||
CHAdeMO | CHAdeMO V1.2/V2.0 | ||
GBT | GB/T 18487.1-2015, GB/T 27930-2015, GB/T 20234.1~3-2015 | ||
EMC/Safety | CE, EN61000-6-3/EN61000-6-1 Class A ; EN 61851-1-2001/EN 61851-21-2001/EN 61851- 22-2001 | UL2202,CE,EN61000-6-3/EN61000-6-1 ClassA; EN 61851-1-2001/EN 61851-21-2001/EN61851-22-2001 | CE, EN61000-6-3/EN61000-6-1 Class A ; EN 61851-1-2001/EN 61851-21-2001/EN 61851-22-2001 |
Solution
Online Inquiry